Yokogawa Digital Computer Corporation.

go to Japanese Web site
Yokogawa Group
 
 
RAMScope

RAMScope GT100/GT110

RAMScope is a tool to monitor and log internal RAM data of MCUs and ECU variables in real time. RAMScope extracts RAM data using debug interface such as NBD*¹, AUD and NEXUS that are implemented in MCUs and ECU variables, enabling to collect data with no effect on a control application.

Since the debug interface makes access to internal RAM using internal DMA or dedicated bus, you can extract RAM data with no burden on a program you are running. And, by observing behavior of a system running via an MCU and logging a result in a file, you can use them for analysis of data or a rare failure.

With GT110*², furthermore, you can monitor and log RAM data and CAN message at the same time, and save necessary ID data on CAN bus and RAM data in a file of CSV format on a same time axis.

*1: NBD (Non Break Debug) is a standardized debug interface based on the ICE
   interface proposed by us in 1996, and mainly used in in-vehicle MCUs for
   automotives.
*2: For details about GT110, please contact us at info-mvi@yokogawa-digital.com.

Features

  • High-speed sampling of max. 128 points/1ms
  • Isolates electrically between a target and the RAMScope main unit with the isolation probe
  • Powerful trigger and graphical display features
  • Supports a wide variety of MCUs by changing the probe, etc.

MCUs supported

Renesas Technology
SH7047, SH7055, SH7058, SH7144, SH7145,
M32176, M32186, M32192, M32196
NEC Electronics
V850E/IA1, V850E/PG2
Freescale Semiconductor
MPC5554, MPC5567

Configuration

Configuration

Item Description
RAMScope Main Unit
GT100, GT110

Main unit to control data collection

Reprogramming internal FPGA for each MCU is required.

Isolation Unit
    +
Control Software

Isolation Unit electrically isolates signals from a target, while converting MCU-specific signals such as NBD, AUD, RTD, etc. to common input signals that can be recognized by RAMScope Main Unit.

Control Software controls RAMScope Main Unit.

Isolation Unit and Control Software specific to each MCU are available.

Interface MCUs supported
GT101H01/CS AUD-I/F SH7047, SH7055, SH7058, SH7144, SH7145
GT101L01/CS RTD-I/F M32176, M32186, M32192, M32196
GT101L02/CS NBD-I/F M32186, M32192, M32196
GT101M01/CS NEXUS-I/F MPC5554, MPC5567
GT101N01/CS NBD-I/F V850E/IA1, V850E/PG2

Specifications

Item Description
OS & Host PC recommended

Windows 2000/XP, CPU: Pentium 3, 1GHz or more with memory of 512MB or more

HDD: 1GB or more free space

Host Interface

USB2.0

Sample Clock

10MHz

Data Collection Sampling Cycle

Example: SH7055: 10μs (min.) to 65535ms (max.)
       M32176: 50μs (min.) to 65535ms (max.)

*Measurement cycle per one point varies depending on MCU.

Measurement Channel

Max. 128 points (which varies depending on MCU)

Data Length

Byte/Word/Long Word/Float

Time Stamp

Min. 10μs

*Time stamp value varies relating to the above sampling cycle value.

Event Detection

8 points

Event is detected by comparing values (= ,> ,<).

Trigger
・Measurement start condition:
Manually/External trigger input
・Measurement stop condition:
Manually/External trigger input/by specifying with delay from an event/by specifying a measurement time
・Trigger Output:
Pulse output: 1ms to 65535ms for H' level width.
Scan output: H' level output during access to a target
Event output: H' level output with event detection
Contents displayed by each window

・List Window displays symbol variable, address and
 monitoring data (hexadecimal/decimal/octal/binary).

・Physical Value Window sets up an expression and
 displays a physical value.

・Overlapping Window For List Window displays multiple
 RAM values (max. 4 waveforms).

・Overlapping Window For Physical Value Window displays
 multiple physical values (max. 4 waveforms).

・Individual Waveform displays RAM value and physical
 value.

Data Storage Project File

Project file has an extension “mmi” and saves environment settings.

Measured Data

Physical Value
(Operation Value)


Measurement result is saved in CSV format on the memory of a PC (in either main memory or HDD of a PC.)

Storage Size:
When using main memory: 128MB
When using HDD: 512MB
             (10ms or more of sampling cycle)
*Storage size varies when a PC has extended memory.
External Dimension

Main Unit: 105 (W) × 75 (D) × 30.2 (H) mm

Probe: 67 (W) × 50 (D) × 19 (H) mm

Operating Environments

Temperature: 5 to 40°C

Humidity: 20 to 80% RH (no condensation)


GT100 Connection Example

GT100接続例

GT110 Connection Example

GT110接続例
   
(C)2002~ Yokogawa Digital Computer Corporation. All Rights Reserved Term of use Privacy Policy