RAMScope GT100/GT110
RAMScope is a tool to monitor and log internal RAM data of MCUs and ECU variables in real time. RAMScope extracts RAM data using debug interface such as NBD*¹, AUD and NEXUS that are implemented in MCUs and ECU variables, enabling to collect data with no effect on a control application.
Since the debug interface makes access to internal RAM using internal DMA or dedicated bus, you can extract RAM data with no burden on a program you are running. And, by observing behavior of a system running via an MCU and logging a result in a file, you can use them for analysis of data or a rare failure.
With GT110*², furthermore, you can monitor and log RAM data and CAN message at the same time, and save necessary ID data on CAN bus and RAM data in a file of CSV format on a same time axis.
- *1: NBD (Non Break Debug) is a standardized debug interface based on the ICE
interface proposed by us in 1996, and mainly used in in-vehicle MCUs for
automotives.
- *2: For details about GT110, please contact us at info-mvi@yokogawa-digital.com.
Features
- High-speed sampling of max. 128 points/1ms
- Isolates electrically between a target and the RAMScope main unit with the isolation probe
- Powerful trigger and graphical display features
- Supports a wide variety of MCUs by changing the probe, etc.
MCUs supported
- Renesas Technology
- SH7047, SH7055, SH7058, SH7144, SH7145,
- M32176, M32186, M32192, M32196
- NEC Electronics
- V850E/IA1, V850E/PG2
- Freescale Semiconductor
- MPC5554, MPC5567
Configuration
| Item |
Description |
RAMScope Main Unit
GT100, GT110 |
Main unit to control data collection
Reprogramming internal FPGA for each MCU is required. |
Isolation Unit
+
Control Software |
Isolation Unit electrically isolates signals from a target, while converting MCU-specific signals such as NBD, AUD, RTD, etc. to common input signals that can be recognized by RAMScope Main Unit.
Control Software controls RAMScope Main Unit.
Isolation Unit and Control Software specific to each MCU are available. |
| Interface |
MCUs supported |
| GT101H01/CS |
AUD-I/F |
SH7047, SH7055, SH7058, SH7144, SH7145 |
| GT101L01/CS |
RTD-I/F |
M32176, M32186, M32192, M32196 |
| GT101L02/CS |
NBD-I/F |
M32186, M32192, M32196 |
| GT101M01/CS |
NEXUS-I/F |
MPC5554, MPC5567 |
| GT101N01/CS |
NBD-I/F |
V850E/IA1, V850E/PG2 |
Specifications
| Item |
Description |
| OS & Host PC recommended |
Windows 2000/XP, CPU: Pentium 3, 1GHz or more with memory of 512MB or more
HDD: 1GB or more free space |
| Host Interface |
USB2.0 |
| Sample Clock |
10MHz |
| Data Collection |
Sampling Cycle |
Example: SH7055: 10μs (min.) to 65535ms (max.)
M32176: 50μs (min.) to 65535ms (max.)
*Measurement cycle per one point varies depending on MCU. |
| Measurement Channel |
Max. 128 points (which varies depending on MCU) |
| Data Length |
Byte/Word/Long Word/Float |
| Time Stamp |
Min. 10μs
*Time stamp value varies relating to the above sampling cycle value. |
| Event Detection |
8 points
Event is detected by comparing values (= ,> ,<). |
| Trigger |
- ・Measurement start condition:
- Manually/External trigger input
- ・Measurement stop condition:
- Manually/External trigger input/by specifying with delay from an event/by specifying a measurement time
- ・Trigger Output:
- Pulse output: 1ms to 65535ms for H' level width.
- Scan output: H' level output during access to a target
- Event output: H' level output with event detection
|
| Contents displayed by each window |
・List Window displays symbol variable, address and monitoring data (hexadecimal/decimal/octal/binary).
・Physical Value Window sets up an expression and displays a physical value.
・Overlapping Window For List Window displays multiple RAM values (max. 4 waveforms).
・Overlapping Window For Physical Value Window displays multiple physical values (max. 4 waveforms).
・Individual Waveform displays RAM value and physical value. |
| Data Storage |
Project File |
Project file has an extension “mmi” and saves environment settings. |
Measured Data
Physical Value
(Operation Value)
|
Measurement result is saved in CSV format on the memory of a PC (in either main memory or HDD of a PC.)
- Storage Size:
- When using main memory: 128MB
- When using HDD: 512MB
(10ms or more of sampling cycle)
- *Storage size varies when a PC has extended memory.
|
| External Dimension |
Main Unit: 105 (W) × 75 (D) × 30.2 (H) mm
Probe: 67 (W) × 50 (D) × 19 (H) mm |
| Operating Environments |
Temperature: 5 to 40°C
Humidity: 20 to 80% RH (no condensation) |
GT100 Connection Example
GT110 Connection Example
|